Request Correction
Use this form to request corrections to the paper metadata. Select the fields that need correction and provide the correct information.
Correction Guidelines
- Click the edit button next to a field to report a correction.
- Fill in the suggested correction value for each field you want to correct.
- Provide your name and email so we can contact you if needed.
Paper Information
CaresAI at CT-DEB’26: Detecting Dosing Errors In Clinical Trials Using Domain-Specific Transformer Embeddings and Classification Models
Paper Fields
Click the edit button next to a field to report a correction.
CaresAI at CT-DEB’26: Detecting Dosing Errors In Clinical Trials Using Domain-Specific Transformer Embeddings and Classification Models
Medication errors, particularly dosing errors in clinical trials (CT), can lead to patient harm, adverse drug events and worse patient outcomes. Dosing errors are preventable, and early identification can improve trial integrity and mitigate subsequent clinical and financial burden. This study aims to detect dosing errors within CT protocols by evaluating text representations of trial information using transformer-based language models trained on biomedical corpora. CT textual data was encoded using several models, including ClinicalBERT, PubMedBERT, BioBERT, and MedCPT, and integrated with categorical features. These text embeddings were used as input to classical machine learning models and neural network architectures within an experimental framework. Performance was primarily assessed using ROC-AUC with respect to predicting dosage error. Under a logistic regression baseline, BioBERT consistently outperformed alternative encoders, achieving an ROC-AUC of 0.794, a 3.95 % improvement over the ClinicalBERT baseline. Combining multiple embeddings did not yield improvements, indicating that domain alignment outweighs representational stacking. Gradient boosting models, support vector classifiers, logistic regression, and residual neural networks achieved the strongest performance for predicting dosage error, achieving ROC-AUCs: 0.821 to 0.853. Overall, the integration of domain-specific transformer embeddings with structured metadata enables discrimination of trials meeting a predefined elevated dosing error risk criterion, advancing safety monitoring and supporting informed regulatory decision-making.
Authors
Expand an author to correct their information. Use the remove button to request author removal, or add a new author.
PDF Attachment
You may attach a PDF as a corrected version of the paper. Max file size: 10MB. Only PDF files are accepted.
Your Information
Author Declaration *
Select at least one field to correct using the edit buttons above.